Firmware Version 091


BN : AXS-024, February 5, 1998

 

  1. A Test Day of the Week instruction has been added to the AXS firmware. The instruction is a ‘detect’ instruction and works the same as the Test Time of Day feature. This means that the instruction immediately following the ‘test’ instruction must be a "what if it fails" instruction which is skipped upon success of the detect instruction. The instruction number is 85XY where X is the number of the start day and Y is the number of the finish day, where 1 = Monday and 7 = Sunday.

        Therefore, to check to see if the day is a week day the instruction would be as follows

                        8515 97 6000 93 95 99

  1. The 123 Power Up Reset, that is to be performed before programming, has been modified slightly. The timing of the reset has been changed. Upon power up there is a delay of 1 second before the dialer splits.
  1. There is now an 8 digit number that is output by the dialer at power up along with the regular sign on message. This 8 digit number is an information message used by the Telcom Research Engineers. After Power Up you will see F0 F0 FF 01 included in the normal sign on message.

Copyright© 2011 Telcom Research
Last modified: October 16, 2011